Showing posts with label Radio Link Failure. Show all posts
Showing posts with label Radio Link Failure. Show all posts

Friday, 2 August 2019

3GPP Minimization of Drive Test (MDT) Signaling at a Glance

There are growing numbers of UEs that are capable of reporting 3GPP-defined measurements for the purpose of minimization of drive test as defined in 3GPP TS 37.320. Although only a subset of the capable devices have this feature enabled it is worth to have a closer look at the signaling procedures and measurements.

3GPP MDT data can be gathered in two different modes: immediate and logged.

immediate mode – as illustrated in figure 1 - provides measurements for RAN and UE. The UE measurements are derived from RRC measurement reports. The RAN adds the power headroom reported on the MAC layer, and the Received Interference Power (RIP) measured on the physical radio interface layer at the cell`s antenna as well as, reports for the data volume, IP throughput, user plane packet delay, and packet loss measured by the eNodeB.
Figure 1: Immediate 3GPP MDT Measurements*

logged mode – an example is shown in Figure 2 - the UE stores information related to accessibility problems in IDLE mode, failures during RRC establishment, and handover random access as well as radio link failures including connection loss. The MDT events log is sent to the network when it is requested. After connection loss, the MDT logged mode report is sent after the next successful radio connection establishment.

Figure 2: Logged 3GPP MDT Measurements*

The RRC measurement samples and Radio Link Failure (RLF) reports also contain detailed location information for example, on GPS/GNSS coordinates, although the 3GPP Release 9 Technical Report TR 36.805 stated: “The extensive use of positioning component of the UE shall be avoided since it would significantly increase the UE power consumption.”

Although, the encoding of logged mode reports and immediate UE measurements are defined in 3GPP TS 36.331 (RRC), the message formatting of the immediate RAN measurement events follow different proprietary specifications of the network element manufacturers (NEMs).

It is also up to the NEMs which of the M2... M7 immediate reports are implemented and how often such measurements will be generated during an ongoing connection. 

* all parameter values shown in the figures have been chosen randomly for illustrative purpose and do not reflect the situation of a real call or network